Records retention guidelines: DRAFT (June 2005)

Introduction

The following records retention guidelines provide recommendations for the disposition of records created or maintained during the routine maintenance and repair of campus facilities. They complement Facilities Management Department Standard Practice number 14, revision 1 (June 4, 2001).

These guidelines apply to facilities management records and data stored on any and all media. They do not apply to records or data sets not otherwise listed in the guidelines, nor do they obligate an office to create a record or data set that previously did not exist.

Fiscal Records

Some information used in the management and oversight of facilities is financial in nature. An office should follow procedures laid out in Financial Services’ General Accounting Procedure 200.240, Retention Periods for Accounting Records, to dispose of fiscal records.

Electronic Records

Facilities Management relies almost exclusively on electronic or “born digital” records created with word processing, computer aided drawing, spreadsheet, electronic mail, website authoring, or database programs to carry out its business and activities. While the all-encompassing term “records” includes any recorded information stored on any medium, the guidelines attempt to recognize that a series may contain paper and electronic records. As electronic records are created, managed, and stored throughout their life cycle of usefulness, these guidelines should serve as a general strategy for identifying basic retention needs for different sets of information.

Using the Retention Guidelines

The retention guidelines identify minimum retention periods for facilities management records. Records not identified in these guidelines should not be disposed of without first consulting the unit AD the University Archivist or the Medical Center Archivist. Records that are involved in an investigation, legal action or proceeding, audit, or program review, whether forthcoming or in progress, should be retained until the resolution of those actions.

Following the minimum retention period, the records in question should be disposed of according to the recommendations in these guidelines. In some cases it is important to destroy information (excluding records identified for permanent retention) using a method that preserves its confidentiality. Duke University maintains contracts with several shredding facilities; visit Procurement Services’ website at http://www.procurement.duke.edu/ for more information.

If you need assistance or guidance in transferring records to the University or Medical Center Archives, visit (or call)
http://library.duke.edu/uarchives/ (919-660-5820) or http://archives.mc.duke.edu (919-383-2653).

The University Records Manager will review the retention guidelines for facilities management records periodically and will issue revisions as necessary and with the assistance of FMD staff.

If you maintain records that are not identified in these guidelines, visit http://library.duke.edu/uarchives/about/records-management/ or call 919-684-6181 for assistance.

Off-site Storage

In most cases, offices do not have adequate space to store records beyond one or two years following their administrative usefulness. If records must be moved to an off-site storage location, consider the following needs:

  • Access and retrieval, including frequency of retrieval, emergency access needs, and potential costs associated with getting to the records;
  • Environmental levels that provide stable and friendly conditions for the records;
  • Security systems that prevent unauthorized access to the records;
  • Filing systems that permit the rapid retrieval of records via a logical index, box list, or similar finding aid; and,
  • The overall physical and intellectual control over the records for which you are the guardian.


Abbreviations and Definitions

Administrative Value —the usefulness of a record in the conduct of office business

Minimum Retention —the minimum amount of time a particular series of records should be retained

Permanent —an indefinite retention period; signifies that the records have sufficient value or importance to justify keeping them in perpetuity. Permanent retention also may be based on legal requirements or demonstrated and justifiable need. Long term or permanent retention of electronic records commits an office’s resources to data migration, ensuring the integrity and trustworthiness of the data, and addressing hardware/software obsolescence. An office should consider the long-term availability of its resources prior to expressing an interest in retaining information permanently. The University Archives
is the official repository for information with historical or enduring value.

Records —all recorded information, regardless of its physical form or characteristics, created or received pursuant to the transaction of University business or in the fulfillment of its educational, administrative, business, or legal obligations.

Record Series (or Series) —a group/set of identical or related records, information, or data that are normally used and filed or stored as a logical unit; synonymous with data set.

Top of Page

Duke University Records Retention Guidelines

Category Description: Facilities Management Department -- Records concerning the maintenance, repair and minor alteration of virtually all campus
facilities.

Primary Heading: Business Services

Series Title Content Minimum Retention Notes
Account reconciliations - G/L accounts   Current fiscal year + 2 years  
Documentation of reconciliation of financial transactions   Current fiscal year + 2 years  
Financial statements (departmental copy) Copies of financial statements Current fiscal year + 1 year Original in Accounting Services
Gross pay distribution sheets   Current fiscal year Original in Corporate Payroll
Invoices Copies of invoices from uniform vendors 1 year Original in Accounts Payable
Journal vouchers Paper copies of journal vouchers Current fiscal year + 1 year Original in Accounting Services; original R3 entry supporting documentation has minimum retention of current fiscal year + 7 years
Packing slips Copies of packing slips attached to received goods 3 months  
Procurement card documentation Receipts, charge slips, statements, etc. Current fiscal year + 7 years Following period of usefulness, records may be stored off-site for remainder of retention period
Timecards Copies of timecards for biweekly employees Current fiscal year + 1 year Original in Corporate Payroll
Work order accounting sheets Top copy of accounting sheet used to log work orders completed by each employee and determine billing for customers Original: current fiscal year + 1 year; supervisor's copy: 1 year  

 Top of page


Primary Heading: Construction Services

Series Title Content Minimum Retention Notes

Construction project records

Project specifications and drawings, CAD drawings, certificates of occupancy, change orders, certificates of substantial completion, financial records, etc.

Financial records - follow guidelines in GAP 200.240; remaining records - permanent

See FMD Standard Practice #14, rev. 1, "File Retention, Storage and Destruction Procedure"

Design and construction agreements   7 years after completion of project if not involved in official action See FMD Standard Practice #14, rev. 1, "File Retention, Storage and Destruction Procedure"
Notices to proceed Issued to contractors 7 years after completion of project if not involved in official action See FMD Standard Practice #14, rev. 1, "File Retention, Storage and Destruction Procedure"

Top of page

Primary Heading: Electrical Services

Series Title Content Minimum Retention Notes

Contracts

Copies of contracts relating to electrical services construction projects

Until no longer useful

Original contracts in Construction Services

Electrical Services reference material and reports Reference materials and reports concerning power outages, demand projections, etc. Until no longer useful  
High Voltage vendor database Electronic database used to track standing orders with vendors, expenditures for electrical projects, etc. Update as necessary; retain data until no longer useful  
Meter readings database Electronic database used to determine billing for usage and analyze campus growth Update as necessary; retain data until no longer useful  
PCB reports Reports detailing removal of electrical transformers and PCBs (polychlorinated biphenyls) Permanent  
Project files Estimates, correspondence with contractors or project managers, purchasing records, copies of blueprints (as-builts and revisions), copies of permits, etc. created for electrical services and high voltage projects Until no longer usef

Top of page

Primary Heading: Grounds, Sanitation and Recycling Services

Series Title Content Minimum Retention Notes
Grounds/sanitation worker time records List time spent on litter control by employee; includes project code, vehicle number, etc. Current fiscal year + 1 year Data from these records is entered into the TRIMS database
Moving and storage records ("p" forms) Forms used to track materials moved and stored, as well as "owner" information and fund codes, into and out of FMD warehouse space 3 years  
Quarry records Summaries of stone taken from Duke's quarry (primarily tonnage) and delivered to project site, correspondence with masons and stone contractors, purchase orders, etc. Destroy purchase orders after current year + 5 years; transfer remaining records to Archives when administrative value ends University Archives has documentation about the quarry in its "Buildings File"
Sanitation tipping tickets Landfill tipping tickets for sanitation and recycling deliveries 1 year  
TRIMS database Electronic database containing equipment inventories and maintenance records, campus tree inventories, grounds and sanitation workers' time records, and other related data.

Update as necessary; retain data until no longer useful

Destroy TRIMS reports when administrative value ends

 
Vehicle records Purchase and repair/maintenance records and vehicle registration records Final disposition of vehicle/equipment Records maintained by vehicle number

Top of page


Primary Heading: Maintenance Services

Series Title Content Minimum Retention Notes
7i Work Requests Electronic work requests submitted via Datastream 7i system; each request identifies work request number, type, equipment, cost code, date created & reported, etc. Archive when no longer useful; retain indefinitely  
As-built drawings Copies of as-built drawings of facilities distributed to shops Until no longer useful  
Equipment and operating manuals   Until no longer useful  
Warranties Warranties for equipment, roofing materials, etc. Until expired and no longer useful  

Top of page


Primary Heading: Steam Plant Services 

Series Title Content Minimum Retention Notes

Blueprints

Hardcopy and digital copies of blueprints of steam plant facilities

Until no longer useful

 
Control systems data Historical data collected from steam plant control systems, such as production, pressures, temperatures, etc. Retain data until no longer useful  
Deliveries database Database containing information about fuel deliveries for the Steam Plant, such as tonnage, sulfur content, etc. Update as necessary; retain data until no longer useful  
Environmental Protection Agency (EPA) reports Reports concerning emissions, fuel consumption, sulfur content analyses, and supporting data 2 years  
Equipment and operating manuals   Until no longer useful  
Logs Hourly and daily logs (paper and electronic) of steam plant readings Paper - 2 years; retain electronic data until no longer useful  
Permits Emissions permits issued by NC Department of Environment and Natural Resources Safety Office 5 years Permits must be renewed every 5 years and are also on file with Occupational & Environmental
Steam production and demand database Database containing information about steam plant production and demand Update as necessary; retain data until no longer useful  

 
Top of page

 

follow us on Twitter follow us on Facebook follow us on YouTube follow us on Flickr follow us on Pinterest follow our blogs and feeds

Contact Us919-660-5870
(Perkins Circulation Desk)

Home | Libraries | Ask Us Now | Catalog | Hours | Library Web Site Search | Site Index

Mobile Library Home (content for handheld devices such as cellphones)

Creative Commons License

Unless otherwise specified on this page, this work is licensed under a
Creative Commons Attribution-Noncommercial-Share Alike 3.0 United States License.


Last modified November 23, 2011 3:32:01 PM EST